Examine This Report on Astm F2170 Relative Humidity Rh Test



ATTAR (Advanced Technology Testing & Research)
44/48 Rocco Dr, Scoresby VIC 3179, Australia
+61 1300 139 155
https://maps.app.goo.gl/RoEp6iupmJCuiUxk6

When it comes to ensuring safety in business, industrial, and domestic spaces, slip resistance testing is a vital element. At ATTAR (Advanced Technology Testing & Research), we specialize in floor slip resistance testing, concrete moisture testing, and luminance contrast analysis to help businesses and property owners alleviate threats and comply with safety requirements.

With state-of-the-art equipment such as the pendulum slip test device and moisture meter for concrete, we provide precise and independent slip testing services across Australia. Our competence covers ASTM F2170 compliance, R Rating evaluations, P Rating tiles, and more, ensuring your floorings satisfy the greatest safety criteria.

Why Slip Resistance Testing is Necessary


Slips and falls are among the leading causes of office and public injuries. Proper slip testing assists identify dangerous surfaces before mishaps take place. Whether you require damp pendulum test evaluations or pendulum test for slip resistance, ATTAR delivers accurate outcomes to boost security.

Key Services Provided by ATTAR


1. Floor Slip Resistance Testing

- Pendulum slip test (AS 4663).
- R Ranking and P Ranking tiles evaluations.
- Independent slip testing services for compliance.

2. Concrete Moisture Testing

- Slab moisture test utilizing sophisticated moisture meter for concrete.
- ASTM F2170 compliant assessments.
- Concrete slab moisture testing to prevent floor covering failures.

3. Luminance Contrast Testing

- Ensures visibility for aesthetically impaired people.
- Complies with Australian accessibility standards.

4. On-Site & Lab Testing

- Slip test machine for accurate on-site assessments.
- Wet pendulum test for damp surface area slip resistance.

Understanding Slip Resistance Ratings: R Score vs. P Score


When carrying out slip resistance testing, 2 crucial classifications are used:.

- R Rating (Ramp Test - DIN 51130)
Steps slip resistance under lubricated conditions, commonly used in Europe.

- P Rating (Pendulum Test - AS 4586)
Assesses dynamic friction using a pendulum test slip resistance machine, widely embraced in Australia.

ATTAR supplies independent slip testing to figure out whether your flooring fulfills the needed pendulum rating tiles standards.

The Value of Concrete Moisture Testing


Excess moisture in concrete slabs can lead to flooring failures, mold development, and adhesive deterioration. Our concrete moisture testing services include:.

> ASTM F2170 certified in-situ relative humidity testing.
> Moisture meter for concrete evaluations.
> Slab moisture test to make sure ideal conditions for floor installations.

By finding moisture concerns early, we assist avoid pricey repair work and guarantee long-lasting flooring performance.

Luminance Contrast for Accessibility Compliance


Correct luminance contrast is vital for aesthetically impaired people to navigate spaces securely. ATTAR assesses:.

> Stair here edges.
> Door frames.
> Handrails.
> Tactile indicators.

Our evaluations guarantee compliance with Australian Impairment Standards (AS 1428.1).

Why Choose ATTAR for Slip Resistance & Moisture Testing?


> NATA Accredited (where relevant).
> Advanced Testing Equipment (pendulum slip test, moisture meters).
> Nationwide Service Coverage.
> Quick & Trustworthy Reporting.

For professional slip resistance testing, floor slip resistance testing, and concrete moisture testing, contact ATTAR (Advanced Technology Testing & Research):.

Address: 44/48 Rocco Dr, Scoresby VIC 3179, Australia.
Phone: +61 1300 139 155.

Common Applications of Slip Resistance Testing


1. Commercial & Retail Spaces

Shopping center, dining establishments, and offices need safe flooring to prevent consumer and worker injuries. Our pendulum slip test guarantees compliance with safety guidelines.

2. Industrial & Storage Facility Facilities

High-traffic industrial environments require resilient, slip-resistant flooring. ATTAR's slip testing services help maintain office safety.

3. Health Care & Aged Care Facilities

Health centers and retirement home must minimize slip threats. Our luminance contrast and slip resistance testing guarantee safe mobility for clients and staff.

4. Public Facilities

Walkways, train stations, and federal government structures require independent slip testing to satisfy availability and safety requirements.

How ATTAR Carries Out Slip Resistance Testing


Step 1: Surface Assessment

We examine flooring materials and conditions (dry, damp, or contaminated).

Action 2: Pendulum Slip Test (AS 4663)

Using a slip test device, we determine the dynamic coefficient of friction (DCOF).

Step 3: Wet Pendulum Test

Imitates slippery conditions to assess real-world slip dangers.

Step 4: Reporting & Compliance Accreditation

Detailed reports with R Ranking or P Rating tiles categories.

The Science Behind Pendulum Slip Testing


The pendulum test slip resistance method includes a swinging arm with a rubber slider that imitates a foot's motion. The test measures:.

- Slip Prospective Worth (SPV).
- Pendulum score tiles classification (P0 to P5).

Greater rankings (P4/P5) indicate better slip resistance.

Moisture Testing for Concrete Floors: Avoiding Failures


Moisture-related floor covering failures can be costly. ATTAR's concrete slab moisture testing includes:.

- ASTM F2170 in-situ RH probes.
- Moisture meter for concrete check.
- Slab moisture test information analysis.

Conclusion


ATTAR (Advanced Technology Testing & Research) is Australia's trusted supplier of slip resistance testing, floor slip resistance testing, concrete moisture testing, and luminance contrast evaluations. With advanced technology like the pendulum slip test and moisture meter for concrete, we provide precise, independent, and certified testing services.

Ensure your residential or commercial property fulfills security requirements-- contact ATTAR today:.

44/48 Rocco Dr, Scoresby VIC 3179, Australia.
+61 1300 139 155.

By choosing ATTAR, you invest in independent slip testing services, pendulum test slip resistance accuracy, and long-lasting floor security options. Let us help you produce more secure, compliant, and moisture-resistant environments.

Leave a Reply

Your email address will not be published. Required fields are marked *